免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人水通道蛋白4(AQP4)酶聯(lián)免疫吸附檢測試劑盒
ELK1468
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human AQP4(Aquaporin 4) ELISA Kit
Reactivity: Human
Alternative Names: HMIWC2; MIWC; WCH4; Mercurial-insensitive water channel
Assay Type: Sandwich
Sensitivity: 0.056 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Infection immunity;Neuro science;
Uniprot ID: P55087
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AQP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AQP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AQP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AQP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.043 1.957
5.00 1.527 1.441
2.50 1.128 1.042
1.25 0.928 0.842
0.63 0.539 0.453
0.32 0.347 0.261
0.16 0.208 0.122
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant AQP4 and the recovery rates were calculated by comparing the measured value to the expected amount of AQP4 in samples.
Matrix Recovery range Average
serum(n=5) 94-107% 100%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AQP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-100% 84-99% 85-97% 88-102%
EDTA plasma(n=5) 92-105% 82-92% 86-94% 81-95%
Heparin plasma(n=5) 86-97% 88-95% 92-101% 87-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
嘉荫县| 禄劝| 巴南区| 桐城市| 桦南县| 商丘市| 连州市| 罗平县| 通许县| 舞阳县| 沙坪坝区| 潼关县| 永济市| 山丹县| 静乐县| 金川县| 嫩江县| 宁夏| 灵宝市| 乐东| 法库县| 云霄县| 济宁市| 息烽县| 富源县| 日土县| 都匀市| 根河市| 黎城县| 东海县| 南溪县| 古交市| 洛阳市| 尼木县| 辉县市| 宁蒗| 湾仔区| 五家渠市| 广安市| 河北省| 和平县|