免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠內(nèi)皮型一氧化氮合酶(NOS3)酶聯(lián)免疫吸附檢測試劑盒
ELK1501
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat NOS3(Nitric Oxide Synthase 3, Endothelial) ELISA Kit
Reactivity: Rat
Alternative Names: ECNOS; NOS III; E-NOS; C-NOS; ENOS; CNOS; Constitutive NOS
Assay Type: Sandwich
Sensitivity: 0.59 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Cardiovascular biology;
Uniprot ID: Q62600
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat NOS3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat NOS3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat NOS3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat NOS3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 1.809 1.707
50.00 1.558 1.456
25.00 1.183 1.081
12.50 0.827 0.725
6.25 0.406 0.304
3.13 0.377 0.275
1.57 0.216 0.114
0.00 0.102 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NOS3 and the recovery rates were calculated by comparing the measured value to the expected amount of NOS3 in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NOS3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-102% 81-96% 93-106% 82-95%
EDTA plasma(n=5) 88-103% 86-97% 87-102% 89-101%
Heparin plasma(n=5) 87-98% 92-101% 82-98% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
汉沽区| 堆龙德庆县| 民权县| 海伦市| 新营市| 辽中县| 肃北| 县级市| 塔城市| 隆安县| 长汀县| 仁化县| 贵定县| 库尔勒市| 金山区| 罗山县| 蕉岭县| 焦作市| 铁力市| 治多县| 华坪县| 永丰县| 奉化市| 织金县| 宣化县| 曲阜市| 神木县| 来宾市| 蒙山县| 临泽县| 安阳县| 河源市| 克拉玛依市| 无极县| 沙田区| 永济市| 特克斯县| 淮阳县| 定州市| 石柱| 永宁县|