免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人腫瘤蛋白p53(TP53)酶聯(lián)免疫吸附檢測試劑盒
ELK1507
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human TP53(Tumor Protein p53) ELISA Kit
Reactivity: Human
Alternative Names: p53; LFS1; TRP53; Li-Fraumeni Syndrome; Cellular tumor antigen p53; Antigen NY-CO-13; Phosphoprotein p53; Tumor suppressor p53
Assay Type: Sandwich
Sensitivity: 27 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Tumor immunity;
Uniprot ID: P04637
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TP53. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TP53. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TP53, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TP53 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
5000.00 1.954 1.865
2500.00 1.653 1.564
1250.00 1.217 1.128
625.00 0.865 0.776
312.50 0.623 0.534
156.25 0.354 0.265
78.13 0.227 0.138
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TP53 and the recovery rates were calculated by comparing the measured value to the expected amount of TP53 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TP53 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-97% 88-102% 85-93% 83-97%
EDTA plasma(n=5) 87-102% 87-96% 92-101% 83-96%
Heparin plasma(n=5) 85-97% 93-101% 97-103% 91-99%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
泰顺县| 邢台市| 沙湾县| 百色市| 墨玉县| 三穗县| 黄浦区| 民勤县| 富川| 页游| 滦南县| 车致| 中卫市| 宁津县| 澄迈县| 泰安市| 航空| 伊金霍洛旗| 泊头市| 博乐市| 汪清县| 双流县| 甘肃省| 安达市| 墨江| 玛多县| 商丘市| 专栏| 东明县| 辉南县| 会宁县| 广德县| 秀山| 土默特左旗| 莱阳市| 日土县| 沂水县| 汉沽区| 湘阴县| 吴忠市| 南平市|