免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人腺苷酸環(huán)化酶1(ADCY1)酶聯(lián)免疫吸附檢測試劑盒
ELK1533
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human ADCY1(Adenylate Cyclase 1, Brain) ELISA Kit
Reactivity: Human
Alternative Names: AC1; ATP pyrophosphate-lyase 1; Ca(2+)/calmodulin-activated adenylyl cyclase; Adenylate cyclase type I
Assay Type: Sandwich
Sensitivity: 0.29 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Neuro science;
Uniprot ID: Q08828
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ADCY1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ADCY1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ADCY1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ADCY1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.164 2.060
25.00 1.599 1.495
12.50 1.123 1.019
6.25 0.847 0.743
3.13 0.525 0.421
1.57 0.386 0.282
0.79 0.232 0.128
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADCY1 and the recovery rates were calculated by comparing the measured value to the expected amount of ADCY1 in samples.
Matrix Recovery range Average
serum(n=5) 95-104% 98%
EDTA plasma(n=5) 82-90% 86%
Heparin plasma(n=5) 84-92% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADCY1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 85-94% 87-101% 89-99%
EDTA plasma(n=5) 91-102% 89-97% 86-102% 94-106%
Heparin plasma(n=5) 82-94% 85-96% 78-90% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
凤翔县| 丹棱县| 卓资县| 同仁县| 紫云| 漾濞| 精河县| 红河县| 赤壁市| 页游| 长泰县| 丁青县| 英超| 任丘市| 普兰店市| 林州市| 富民县| 房山区| 印江| 柘荣县| 河北省| 玛纳斯县| 西吉县| 博兴县| 中超| 云梦县| 邯郸市| 泌阳县| 乐山市| 汝南县| 宝兴县| 陇南市| 任丘市| 读书| 晋州市| 尼木县| 兴仁县| 金平| 辽宁省| 梓潼县| 荥经县|