免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人脂肪分化相關(guān)蛋白(ADRP)酶聯(lián)免疫吸附檢測試劑盒
ELK1534
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human ADRP(Adipose Differentiation Related Protein) ELISA Kit
Reactivity: Human
Alternative Names: PLIN2; ADFP; Adipophilin; Perilipin 2
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;
Uniprot ID: Q99541
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ADRP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ADRP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ADRP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ADRP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.368 2.276
5.00 1.674 1.582
2.50 1.114 1.022
1.25 0.878 0.786
0.63 0.555 0.463
0.32 0.385 0.293
0.16 0.234 0.142
0.00 0.092 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADRP and the recovery rates were calculated by comparing the measured value to the expected amount of ADRP in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 88-103% 95%
Heparin plasma(n=5) 92-106% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADRP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 85-92% 79-96% 89-100%
EDTA plasma(n=5) 83-94% 80-92% 86-102% 87-103%
Heparin plasma(n=5) 81-97% 88-102% 85-93% 83-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
夹江县| 西城区| 金山区| 昌黎县| 喀喇| 威海市| 鄂伦春自治旗| 沾益县| 泽州县| 丽水市| 丹巴县| 清水河县| 和政县| 体育| 涪陵区| 信丰县| 金川县| 咸丰县| 行唐县| 永泰县| 龙泉市| 博白县| 麻城市| 寿光市| 开封县| 武义县| 崇礼县| 山阴县| 苏尼特右旗| 石渠县| 庆阳市| 鱼台县| 蚌埠市| 东宁县| 淮安市| 威海市| 仁怀市| 科尔| 安陆市| 太仓市| 马关县|