免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人回腸脂肪酸結(jié)合蛋白(FABP6)酶聯(lián)免疫吸附檢測試劑盒
ELK1536
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human FABP6(Fatty Acid Binding Protein 6, Ileal) ELISA Kit
Reactivity: Human
Alternative Names: GT; iBABP; I-BABP; I-BALB; I-BAP; ILBP; ILBP3; ILLBP; I-15P; Gastrotropin; Illeal Lipid-Binding Protein; Ileal Bile Acid Binding Protein; Intestinal 15 kDa protein
Assay Type: Sandwich
Sensitivity: 26.9 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;
Uniprot ID: P51161
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FABP6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FABP6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FABP6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FABP6 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
4000.00 2.108 2.010
2000.00 1.647 1.549
1000.00 1.135 1.037
500.00 0.886 0.788
250.00 0.543 0.445
125.00 0.321 0.223
62.50 0.225 0.127
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FABP6 and the recovery rates were calculated by comparing the measured value to the expected amount of FABP6 in samples.
Matrix Recovery range Average
serum(n=5) 94-105% 98%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 80-93% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FABP6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 85-96% 87-101% 89-102%
EDTA plasma(n=5) 93-102% 90-99% 95-106% 87-101%
Heparin plasma(n=5) 88-101% 93-106% 85-95% 92-104%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
大足县| 古丈县| 丰原市| 来宾市| 乐至县| 如皋市| 三门峡市| 桂阳县| 乌恰县| 黑水县| 馆陶县| 富源县| 新泰市| 泽库县| 鄢陵县| 晋州市| 车险| 旬阳县| 新乐市| 民和| 将乐县| 定兴县| 吴桥县| 德兴市| 青冈县| 威远县| 绥中县| 邛崃市| 芦山县| 尚志市| 博乐市| 都匀市| 兰西县| 禄劝| 平乡县| 炎陵县| 北宁市| 托克托县| 游戏| 五台县| 遂川县|