免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人沉默調(diào)節(jié)蛋白2(SIRT2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1537
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human SIRT2(Sirtuin 2) ELISA Kit
Reactivity: Human
Alternative Names: SIR2L; SIR2-L; SIR2L2; Silent Information Regulator 2 Protein; NAD-Dependent Deacetylase Sirtuin-2; Silent Mating Type Information Regulation 2 Homolog
Assay Type: Sandwich
Sensitivity: 0.64 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Developmental science;
Uniprot ID: Q8IXJ6
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SIRT2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SIRT2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SIRT2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SIRT2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.157 2.070
50.00 1.700 1.613
25.00 1.119 1.032
12.50 0.854 0.767
6.25 0.516 0.429
3.13 0.364 0.277
1.57 0.236 0.149
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SIRT2 and the recovery rates were calculated by comparing the measured value to the expected amount of SIRT2 in samples.
Matrix Recovery range Average
serum(n=5) 87-95% 91%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 94-107% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SIRT2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 93-101% 97-103% 91-99%
EDTA plasma(n=5) 90-98% 85-92% 83-96% 93-102%
Heparin plasma(n=5) 79-95% 96-105% 85-96% 90-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
台州市| 镇赉县| 华容县| 华坪县| 汉源县| 巴林左旗| 阳江市| 湄潭县| 广安市| 台南市| 贵南县| 武冈市| 建水县| 甘泉县| 揭东县| 柏乡县| 武定县| 连山| 姜堰市| 潍坊市| 大安市| 西畴县| 罗山县| 邵武市| 中江县| 宜良县| 明光市| 壤塘县| 南阳市| 固阳县| 栖霞市| 乐陵市| 乌兰浩特市| 老河口市| 邛崃市| 台江县| 遵义县| 固安县| 南漳县| 凤凰县| 宁德市|