免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人血紅素氧合酶2(HO2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1547
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human HO2(Heme Oxygenase 2, Decycling) ELISA Kit
Reactivity: Human
Alternative Names: HMOX2
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Tumor immunity;
Uniprot ID: P30519
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HO2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HO2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HO2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HO2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.532 2.439
5.00 1.741 1.648
2.50 1.117 1.024
1.25 0.867 0.774
0.63 0.547 0.454
0.32 0.352 0.259
0.16 0.241 0.148
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HO2 and the recovery rates were calculated by comparing the measured value to the expected amount of HO2 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HO2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-102% 93-106% 87-101% 91-104%
EDTA plasma(n=5) 89-97% 93-102% 81-96% 93-106%
Heparin plasma(n=5) 86-93% 91-105% 87-98% 89-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
沅陵县| 湖州市| 平和县| 黄冈市| 怀宁县| 尚义县| 富平县| 建德市| 绥阳县| 卫辉市| 武冈市| 宁南县| 鄂伦春自治旗| 大冶市| 舞钢市| 曲麻莱县| 定南县| 邵武市| 昌宁县| 濉溪县| 凤冈县| 商水县| 平山县| 闻喜县| 专栏| 集安市| 巴马| 吉首市| 铁力市| 苗栗县| 琼中| 吉木萨尔县| 泰州市| 梧州市| 琼中| 屏东市| 耿马| 沂源县| 江源县| 慈利县| 望都县|