免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人纖溶酶/抗纖溶酶復(fù)合體(PAP)酶聯(lián)免疫吸附檢測試劑盒
ELK1556
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PAP(Plasmin/Antiplasmin Complex) ELISA Kit
Reactivity: Human
Alternative Names: Plasmin/Antiplasmin Complex
Assay Type: Sandwich
Sensitivity: 3.5 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: plasma
Assay Length: 3.5h
Research Area: Signal transduction;Enzyme & Kinase;Hematology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PAP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PAP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PAP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PAP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.302 2.213
250.00 1.609 1.520
125.00 1.157 1.068
62.50 0.826 0.737
31.25 0.558 0.469
15.63 0.305 0.216
7.82 0.206 0.117
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PAP and the recovery rates were calculated by comparing the measured value to the expected amount of PAP in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 91%
EDTA plasma(n=5) 82-94% 88%
Heparin plasma(n=5) 94-105% 98%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PAP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 84-99% 83-101% 86-99% 93-101%
EDTA plasma(n=5) 89-105% 87-98% 92-100% 88-104%
Heparin plasma(n=5) 88-97% 91-105% 87-98% 95-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
姜堰市| 焦作市| 吉林省| 菏泽市| 许昌市| 灵寿县| 安化县| 茂名市| 怀宁县| 高碑店市| 彰化市| 永泰县| 齐河县| 德钦县| 朝阳市| 温州市| 陆河县| 若尔盖县| 房产| 通道| 文安县| 镇巴县| 海丰县| 赣榆县| 碌曲县| 通城县| 盖州市| 始兴县| 海阳市| 渭源县| 通榆县| 贵溪市| 如皋市| 雅安市| 出国| 疏附县| 阿合奇县| 延川县| 鸡东县| 神池县| 宁化县|