Product name: Human F10(Coagulation Factor X) ELISA Kit
Reactivity: Human
Alternative Names: FX; FXA; Stuart Prower Factor; Thrombokinase
Assay Type: Sandwich
Sensitivity: 0.09 ng/mL
Standard: 12 ng/mL
Detection Range: 0.19-12 ng/mL
Sample Type: Plasma.
Assay Length: 3.5h
Research Area: Signal transduction;Hematology;
Uniprot ID: P00742
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human F10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human F10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human F10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human F10 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
12.00 2.052 1.969
6.00 1.711 1.628
3.00 1.175 1.092
1.50 0.897 0.814
0.75 0.567 0.484
0.38 0.357 0.274
0.19 0.252 0.169
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant F10 and the recovery rates were calculated by comparing the measured value to the expected amount of F10 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 94-107% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of F10 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 79-95% 95-102%
EDTA plasma(n=5) 95-102% 97-105% 92-101% 85-92%
Heparin plasma(n=5) 88-97% 79-92% 85-93% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
沂源县| 霞浦县| 乌拉特前旗| 伊金霍洛旗| 神池县| 营口市| 沧州市| 万宁市| 沽源县| 乌鲁木齐市| 齐河县| 廊坊市| 德安县| 遵化市| 留坝县| 清流县| 邯郸县| 桐柏县| 肥西县| 清丰县| 镇原县| 贡嘎县| 略阳县| 岳池县| 台东市| 莱西市| 曲沃县| 天等县| 治县。| 五常市| 滦南县| 桐柏县| 临泽县| 民丰县| 大洼县| 邵阳县| 泌阳县| 德令哈市| 湖北省| 宜宾县| 宣汉县|