免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠含血管性血友病因子A域蛋白1(vWA1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1563
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse vWA1(Von Willebrand Factor A Domain Containing Protein 1) ELISA Kit
Reactivity: Mouse
Alternative Names: VWFA1; WARP
Assay Type: Sandwich
Sensitivity: 12.4 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Plasma.
Assay Length: 3.5h
Research Area: Hematology;
Uniprot ID: Q8R2Z5
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse vWA1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse vWA1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse vWA1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse vWA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 1.933 1.846
1000.00 1.522 1.435
500.00 1.143 1.056
250.00 0.827 0.740
125.00 0.545 0.458
62.50 0.332 0.245
31.25 0.211 0.124
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant vWA1 and the recovery rates were calculated by comparing the measured value to the expected amount of vWA1 in samples.
Matrix Recovery range Average
serum(n=5) 88-99% 93%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 80-97% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of vWA1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 97-106% 92-101% 82-90%
EDTA plasma(n=5) 85-92% 96-103% 87-98% 95-102%
Heparin plasma(n=5) 97-106% 86-92% 91-103% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江川县| 襄城县| 古蔺县| 衡南县| 海淀区| 墨竹工卡县| 武胜县| 石林| 怀来县| 志丹县| 龙川县| 广水市| 正镶白旗| 西平县| 英超| 格尔木市| 绵阳市| 太和县| 双鸭山市| 达拉特旗| 莱西市| 邻水| 禹城市| 阳山县| 怀化市| 潍坊市| 武汉市| 海兴县| 库尔勒市| 湟中县| 利津县| 南岸区| 石台县| 阳信县| 师宗县| 阿拉尔市| 绍兴市| 鄂托克旗| 藁城市| 新疆| 盖州市|