免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人脂蛋白a(Lpa)酶聯(lián)免疫吸附檢測試劑盒
ELK1564
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human Lpa(Lipoprotein, a) ELISA Kit
Reactivity: Human
Alternative Names: Lp(a); AK38; APOA; LP; Sinking Pre-β-Lipoprotein
Assay Type: Sandwich
Sensitivity: 1.48 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;Hepatology;
Uniprot ID: P08519
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Lpa. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Lpa. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Lpa, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Lpa in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
200.00 1.951 1.863
100.00 1.557 1.469
50.00 1.098 1.010
25.00 0.871 0.783
12.50 0.593 0.505
6.25 0.319 0.231
3.13 0.226 0.138
0.00 0.088 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Lpa and the recovery rates were calculated by comparing the measured value to the expected amount of Lpa in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lpa and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 97-106% 89-97% 95-104%
EDTA plasma(n=5) 85-102% 79-92% 87-103% 89-98%
Heparin plasma(n=5) 88-97% 91-98% 86-103% 79-91%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
安仁县| 济南市| 曲阜市| 三门县| 鹤峰县| 奇台县| 宣恩县| 通州市| 陕西省| 莱西市| 炎陵县| 闽侯县| 宾川县| 丹巴县| 汪清县| 昌平区| 永康市| 阜南县| 三都| 潜山县| 沐川县| 海林市| 北流市| 海南省| 藁城市| 宜阳县| 兴化市| 黑河市| 宜州市| 巨鹿县| 丽江市| 德庆县| 图们市| 宜州市| 中西区| 会理县| 英德市| 宾阳县| 怀宁县| 尖扎县| 横峰县|