免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人白介素27(IL27)酶聯(lián)免疫吸附檢測試劑盒
ELK1572
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human IL27(Interleukin 27) ELISA Kit
Reactivity: Human
Alternative Names: IL-27;p28; IL30; Interleukin 30; Interleukin-27 subunit alpha
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: Q8NEV9
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IL27. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IL27. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IL27, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IL27 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.157 2.072
500.00 1.729 1.644
250.00 1.255 1.170
125.00 0.958 0.873
62.50 0.655 0.570
31.25 0.397 0.312
15.63 0.288 0.203
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IL27 and the recovery rates were calculated by comparing the measured value to the expected amount of IL27 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL27 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 82-93% 89-103%
EDTA plasma(n=5) 85-92% 90-96% 87-1028% 85-97%
Heparin plasma(n=5) 88-105% 86-102% 97-106% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
宾川县| 延安市| 平顺县| 张北县| 闻喜县| 白朗县| 文成县| 仁化县| 新宁县| 宁晋县| 丰都县| 句容市| 三原县| 靖江市| 贵德县| 澄江县| 中超| 汝城县| 荔浦县| 获嘉县| 焉耆| 吴旗县| 建宁县| 文登市| 饶平县| 南乐县| 微山县| 崇礼县| 邹平县| 八宿县| 微博| 京山县| 黄龙县| 城固县| 河津市| 堆龙德庆县| 永靖县| 七台河市| 额济纳旗| 海阳市| 泊头市|