免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人糖原磷酸化酶L(PYGL)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1577
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PYGL(Glycogen Phosphorylase, Liver) ELISA Kit
Reactivity: Human
Alternative Names: GPLL; GPBB; Hers Disease; Glycogen Storage Disease Type VI
Assay Type: Sandwich
Sensitivity: 0.115 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Endocrinology;
Uniprot ID: P06737
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PYGL. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PYGL. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PYGL, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PYGL in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.908 1.804
10.00 1.628 1.524
5.00 1.128 1.024
2.50 0.928 0.824
1.25 0.563 0.459
0.63 0.342 0.238
0.32 0.228 0.124
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PYGL and the recovery rates were calculated by comparing the measured value to the expected amount of PYGL in samples.
Matrix Recovery range Average
serum(n=5) 78-95% 86%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 80-96% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PYGL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 92-101% 87-96% 82-90%
EDTA plasma(n=5) 89-105% 90-101% 87-98% 85-92%
Heparin plasma(n=5) 78-92% 79-93% 91-98% 89-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
阿拉尔市| 广汉市| 台中市| 仪征市| 噶尔县| 永昌县| 张家口市| 深州市| 兴海县| 布拖县| 汝城县| 汕头市| 鹤庆县| 汨罗市| 邯郸市| 朝阳县| 武宁县| 绥芬河市| 济宁市| 合江县| 郧西县| 潍坊市| 彭山县| 桂阳县| 柳林县| 绥江县| 八宿县| 临沭县| 民勤县| 连城县| 安西县| 临沭县| 贵溪市| 南岸区| 璧山县| 威远县| 贡嘎县| 甘南县| 元谋县| 友谊县| 武冈市|