免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠低氧誘導因子1α(HIF1a)酶聯(lián)免疫吸附檢測試劑盒
ELK1605
規格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Mouse HIF1a(Hypoxia Inducible Factor 1 Alpha) ELISA Kit
Reactivity: Mouse
Alternative Names: HIF1-Alpha; HIF1-A; MOP1; PASD8; Basic Helix-Loop-Helix Transcription Factor; ARNT-interacting protein; Basic-helix-loop-helix-PAS protein MOP1; Class E basic helix-loop-helix protein 78
Assay Type: Sandwich
Sensitivity: 0.056 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Cardiovascular biology;Reproductive science;
Uniprot ID: Q61221
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse HIF1a. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse HIF1a. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse HIF1a, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse HIF1a in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
10.00 2.401 2.318
5.00 1.779 1.696
2.50 1.194 1.111
1.25 0.831 0.748
0.63 0.563 0.480
0.32 0.313 0.230
0.16 0.252 0.169
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HIF1a and the recovery rates were calculated by comparing the measured value to the expected amount of HIF1a in samples.
Matrix Recovery range Average
serum(n=5) 79-93% 86%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 84-97% 90%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HIF1a and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 92-101% 87-96% 82-90%
EDTA plasma(n=5) 83-97% 92-103% 86-97% 93-101%
Heparin plasma(n=5) 87-96% 86-95% 91-103% 87-93%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
新宁县| 云霄县| 衡南县| 望城县| 台南市| 宁国市| 英超| 漯河市| 化州市| 湛江市| 岗巴县| 房山区| 壶关县| 项城市| 新疆| 长顺县| 宝清县| 忻城县| 平舆县| 曲松县| 巫溪县| 金寨县| 留坝县| 体育| 西青区| 沂南县| 渭南市| 房山区| 门头沟区| 丰原市| 蒙山县| 察隅县| 海晏县| 盘山县| 泰安市| 密云县| 东台市| 河源市| 静乐县| 连江县| 城市|