免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠Ⅳ型膠原(COL4)酶聯(lián)免疫吸附檢測試劑盒
ELK1665
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse COL4(Collagen Type IV) ELISA Kit
Reactivity: Mouse
Alternative Names: Type-IV Collagen
Assay Type: Sandwich
Sensitivity: 0.064 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Hepatology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse COL4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse COL4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse COL4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse COL4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.990 1.906
5.00 1.506 1.422
2.50 1.032 0.948
1.25 0.856 0.772
0.63 0.547 0.463
0.32 0.305 0.221
0.16 0.208 0.124
0.00 0.084 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant COL4 and the recovery rates were calculated by comparing the measured value to the expected amount of COL4 in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 88-102% 95%
Heparin plasma(n=5) 83-98% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of COL4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 87-96% 85-96% 85-95%
EDTA plasma(n=5) 86-96% 93-104% 89-97% 85-94%
Heparin plasma(n=5) 87-96% 85-97% 85-94% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
咸宁市| 佳木斯市| 上饶市| 故城县| 安西县| 马尔康县| 兰西县| 镇平县| 呼伦贝尔市| 金平| 河间市| 高邮市| 鞍山市| 安龙县| 张北县| 贡觉县| 岳阳市| 剑川县| 全椒县| 资兴市| 儋州市| 毕节市| 兰州市| 西昌市| 麻阳| 罗定市| 乐安县| 深州市| 富顺县| 黄冈市| 陈巴尔虎旗| 景宁| 枝江市| 安新县| 五原县| 门头沟区| 灵石县| 长海县| 明溪县| 合川市| 景洪市|