免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人蛋白二硫鍵異構(gòu)酶(PDI)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1669
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PDI(Protein Disulfide Isomerase) ELISA Kit
Reactivity: Human
Alternative Names: P4HB; ERBA2L; PDIA1; PO4DB; PROHB, DSI, GIT, PDI, PO4HB, P4Hbeta; Prolyl 4-Hydroxylase Subunit Beta; Procollagen-Proline 2-Oxoglutarate 4-Dioxygenase Beta Polypeptide
Assay Type: Sandwich
Sensitivity: 0.114 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PDI. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PDI. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PDI, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PDI in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
20.00 1.916 1.828
10.00 1.527 1.439
5.00 1.052 0.964
2.50 0.833 0.745
1.25 0.559 0.471
0.63 0.362 0.274
0.32 0.182 0.094
0.00 0.088 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PDI and the recovery rates were calculated by comparing the measured value to the expected amount of PDI in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 82-95% 88%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PDI and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 82-98% 89-97% 85-93%
EDTA plasma(n=5) 86-93% 91-103% 87-98% 92-99%
Heparin plasma(n=5) 89-99% 83-96% 98-104% 88-101%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
合水县| 黄骅市| 神农架林区| 定兴县| 新兴县| 玛多县| 准格尔旗| 临汾市| 庆元县| 唐海县| 扶绥县| 黄平县| SHOW| 邓州市| 萍乡市| 山东省| 苏尼特右旗| 龙口市| 冕宁县| 容城县| 崇礼县| 老河口市| 滁州市| 潞西市| 岫岩| 平塘县| 公主岭市| 乌拉特前旗| 环江| 寿光市| 汝城县| 腾冲县| 喀什市| 湘乡市| 东安县| 云安县| 连城县| 靖安县| 徐水县| 丰顺县| 济南市|