免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胃泌素釋放肽前體(ProGRP)酶聯(lián)免疫吸附檢測試劑盒
ELK1674
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human ProGRP(Pro-Gastrin Releasing Peptide) ELISA Kit
Reactivity: Human
Alternative Names: pro-GRP; preproGRP; pre-proGRP
Assay Type: Competitive Inhibition
Sensitivity: 4.95 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Tumor immunity;Endocrinology;Reproductive science;Pulmonology;Hepatology;Gastroenterology;Hormone metabolism;
Uniprot ID: P07492
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human ProGRP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ProGRP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ProGRP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 0.179
500.00 0.397
250.00 0.612
125.00 0.897
62.50 1.236
31.25 1.589
15.63 1.733
0.00 2.057

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ProGRP and the recovery rates were calculated by comparing the measured value to the expected amount of ProGRP in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 80-93% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ProGRP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-102% 97-103% 88-96% 95-101%
EDTA plasma(n=5) 95-102% 85-96% 90-98% 82-93%
Heparin plasma(n=5) 82-93% 96-105% 87-98% 85-97%