免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠鈣網(wǎng)蛋白(CRT)酶聯(lián)免疫吸附檢測試劑盒
ELK3182
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Mouse CRT(Calreticulin) ELISA Kit
Reactivity: Mouse
Alternative Names: CALR; RO; SSA; CC1qR; ERp60; HACBP; grp60; CRTC; CRP55; Calregulin; Sicca Syndrome Antigen A; Autoantigen Ro; Endoplasmic reticulum resident protein 60
Assay Type: Sandwich
Sensitivity: 0.067 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Bone metabolism;
Uniprot ID: P14211
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CRT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CRT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CRT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CRT in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.166 2.089
5.00 1.621 1.544
2.50 0.997 0.920
1.25 0.777 0.700
0.63 0.532 0.455
0.32 0.351 0.274
0.16 0.206 0.129
0.00 0.077 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CRT and the recovery rates were calculated by comparing the measured value to the expected amount of CRT in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 89-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CRT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 79-96% 92-101% 83-90%
EDTA plasma(n=5) 95-102% 93-101% 97-105% 95-103%
Heparin plasma(n=5) 88-97% 86-92% 81-93% 89-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
宾川县| 南木林县| 青川县| 铜梁县| 江永县| 连城县| 湖南省| 康马县| 鄂温| 武清区| 宁陵县| 余庆县| 毕节市| 安塞县| 南昌市| 天峻县| 长葛市| 扎兰屯市| 东辽县| 彭泽县| 屏东市| 永善县| 故城县| 石柱| 岳池县| 辉县市| 曲阳县| 孟连| 无棣县| 密山市| 长顺县| 麟游县| 都匀市| 福贡县| 承德市| 曲水县| 金寨县| 麟游县| 新乐市| 嘉荫县| 高台县|