免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠S100鈣結合蛋白A9(S100A9)酶聯(lián)免疫吸附檢測試劑盒
ELK3285
規格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Mouse S100A9(S100 Calcium Binding Protein A9) ELISA Kit
Reactivity: Mouse
Alternative Names: MRP14; MIF; 60B8AG; CFAG; NIF; CAGB; CGLB; L1AG; P14; Calgranulin B; Migration inhibitory factor-related protein 14; Calprotectin L1H subunit; Leukocyte L1 complex heavy chain
Assay Type: Sandwich
Sensitivity: 0.059 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;Rheumatology;
Uniprot ID: P31725
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse S100A9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse S100A9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse S100A9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse S100A9 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
10.00 2.035 1.950
5.00 1.703 1.618
2.50 1.157 1.072
1.25 0.895 0.810
0.63 0.585 0.500
0.32 0.363 0.278
0.16 0.257 0.172
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A9 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A9 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 83-98% 91%
Heparin plasma(n=5) 91-99% 95%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 87-101% 89-102% 85-98%
EDTA plasma(n=5) 86-101% 86-101% 87-96% 92-105%
Heparin plasma(n=5) 89-102% 92-101% 88-102% 87-102%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
漠河县| 静海县| 营口市| 巴青县| 嘉义市| 都兰县| 比如县| 山西省| 安吉县| 阿合奇县| 湘乡市| 德化县| 城口县| 茂名市| 宁国市| 鹤壁市| 迁安市| 阆中市| 平阴县| 房产| 宜宾市| 巴青县| 达州市| 六枝特区| 华阴市| 宁波市| 永昌县| 安乡县| 偏关县| 华阴市| 汤原县| 东安县| 运城市| 巨野县| 瑞昌市| 通山县| 元朗区| 亚东县| 建平县| 嵊州市| 余姚市|