免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人RNA結(jié)合基元蛋白3(RBM3)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK4844
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human RBM3(RNA Binding Motif Protein 3) ELISA Kit
Reactivity: Human
Alternative Names: IS1-RNPL; RNPL; Putative RNA-binding protein 3
Assay Type: Sandwich
Sensitivity: 0.059 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: P98179
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human RBM3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human RBM3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human RBM3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human RBM3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.043 1.960
5.00 1.643 1.560
2.50 1.243 1.160
1.25 0.752 0.669
0.63 0.563 0.480
0.32 0.312 0.229
0.16 0.142 0.059
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant RBM3 and the recovery rates were calculated by comparing the measured value to the expected amount of RBM3 in samples.
Matrix Recovery range Average
serum(n=5) 83-98% 90%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of RBM3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-104% 82-96% 95-102%
EDTA plasma(n=5) 87-98% 92-105% 83-92% 89-98%
Heparin plasma(n=5) 86-98% 83-96% 95-104% 81-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
朝阳县| 福清市| 耿马| 十堰市| 乳山市| 仁化县| 海门市| 云林县| 通许县| 太原市| 尼玛县| 辽源市| 宣威市| 庄浪县| 常山县| 宁海县| 丽水市| 丰都县| 全州县| 横峰县| 寿阳县| 宣汉县| 南康市| 海门市| 太和县| 平塘县| 陆丰市| 平泉县| 恩施市| 金沙县| 分宜县| 平潭县| 云和县| 泾川县| 东乡族自治县| 江川县| 专栏| 汉源县| 兴义市| 庆元县| 光山县|