免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

豬內(nèi)皮型一氧化氮合酶(NOS3)酶聯(lián)免疫吸附檢測試劑盒
ELK5617
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻

Product name: Pig NOS3(Nitric Oxide Synthase 3, Endothelial) ELISA Kit
Reactivity: Pig
Alternative Names: ECNOS; NOS III; E-NOS; C-NOS; ENOS; CNOS; Constitutive NOS
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Cardiovascular biology;
Uniprot ID: Q28969
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pig NOS3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig NOS3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pig NOS3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig NOS3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.218 2.116
500.00 1.509 1.407
250.00 1.043 0.941
125.00 0.866 0.764
62.50 0.535 0.433
31.25 0.359 0.257
15.63 0.232 0.130
0.00 0.102 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NOS3 and the recovery rates were calculated by comparing the measured value to the expected amount of NOS3 in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NOS3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-96% 91-107% 87-101% 95-102%
EDTA plasma(n=5) 85-92% 96-103% 87-98% 95-102%
Heparin plasma(n=5) 97-106% 86-92% 91-103% 89-97%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
霍林郭勒市| 石泉县| 英山县| 三河市| 韩城市| 扎赉特旗| 行唐县| 米泉市| 宝应县| 巴林右旗| 兰溪市| 西宁市| 方正县| 鄂州市| 曲水县| 南安市| 象州县| 萨迦县| 石河子市| 九台市| 专栏| 红桥区| 皋兰县| 崇州市| 新源县| 思南县| 七台河市| 普格县| 双江| 新竹市| 凉城县| 方正县| 合肥市| 文登市| 安福县| 沁源县| 顺平县| 佛冈县| 井研县| 达尔| 浪卡子县|