免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠核因子κB亞基p105(NFKB-p105)酶聯(lián)免疫吸附檢測試劑盒
ELK5691
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Rat NF-κBp105(Nuclear factor NF-kappa-B p105 subunit) ELISA Kit
Reactivity: Rat
Alternative Names: NF-KB1; EBP-1; KBF1; NF-Kappa-B; NFKB-P105; NFKB-P50; Nuclear Factor Of Kappa Light Polypeptide Gene Enhancer In B-Cells 1; Nuclear factor NF-kappa-B p105 subunit; NFkB; Nuclear Factor Kappa B
Assay Type: Sandwich
Sensitivity: 0.114 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: Q63369
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat NF-κBp105. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat NF-κBp105. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat NF-κBp105, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat NF-κBp105 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.379 2.296
10.00 1.621 1.538
5.00 1.115 1.032
2.50 0.735 0.652
1.25 0.555 0.472
0.63 0.298 0.215
0.32 0.223 0.140
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NF-κBp105 and the recovery rates were calculated by comparing the measured value to the expected amount of NF-κBp105 in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 81-93% 87%
Heparin plasma(n=5) 82-94% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NF-κBp105 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 82-91% 86-93% 81-94%
EDTA plasma(n=5) 86-94% 85-95% 89-99% 85-95%
Heparin plasma(n=5) 89-97% 85-94% 79-96% 85-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
西林县| 博罗县| 武清区| 和顺县| 若尔盖县| 芒康县| 尤溪县| 荔波县| 祁东县| 澄江县| 广灵县| 陇西县| 嵊泗县| 舞钢市| 泽普县| 广东省| 容城县| 洛川县| 随州市| 汾西县| 依安县| 翁牛特旗| 宾阳县| 博客| 眉山市| 金沙县| 崇文区| 奉新县| 濮阳县| 遂溪县| 凤山市| 云和县| 泰州市| 陇南市| 北安市| 新干县| 绥滨县| 开平市| 黄龙县| 嘉义市| 喀喇沁旗|