免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

環(huán)磷酸腺苷(cAMP)酶聯(lián)免疫吸附檢測試劑盒
ELK8116
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: cAMP(Cyclic Adenosine Monophosphate) ELISA Kit
Reactivity: General
Alternative Names: c-AMP; 3'-5'-Cyclic Adenosine Monophosphate; Adenosine Cyclophosphate
Assay Type: Competitive Inhibition
Sensitivity: 92.5 pg/mL
Standard: 20000 pg/mL
Detection Range: 312.5-20000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Signal transduction;Metabolic pathway;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with cAMP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to cAMP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of cAMP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
20000.00 0.237
10000.00 0.411
5000.00 0.715
2500.00 0.913
1250.00 1.225
625.00 1.579
312.50 1.813
0.00 2.211

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant cAMP and the recovery rates were calculated by comparing the measured value to the expected amount of cAMP in samples.
Matrix Recovery range Average
serum(n=5) 93-105% 99%
EDTA plasma(n=5) 84-93% 89%
Heparin plasma(n=5) 81-103% 94%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of cAMP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-105% 85-103% 89-97%
EDTA plasma(n=5) 95-104% 93-105% 82-101% 91-103%
Heparin plasma(n=5) 83-95% 96-105% 85-96% 90-99%