免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠糖胺聚糖(GAGs)酶聯(lián)免疫吸附檢測試劑盒
ELK8486
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Rat GAGs(Glycosaminoglycan) ELISA Kit
Reactivity: Rat
Alternative Names: Mucopolysaccharide; GAGs;
Assay Type: Competitive Inhibition
Sensitivity: 0.51 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Tumor immunity;Hepatology;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat GAGs protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat GAGs. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat GAGs in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 0.199
50.00 0.389
25.00 0.593
12.50 0.861
6.25 1.157
3.13 1.537
1.57 1.789
0.00 2.256

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GAGs and the recovery rates were calculated by comparing the measured value to the expected amount of GAGs in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 85-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GAGs and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 92-101% 80-93% 89-97%
EDTA plasma(n=5) 85-92% 79-96% 89-100% 85-96%
Heparin plasma(n=5) 85-94% 85-96% 92-102% 81-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
房产| 道孚县| 德保县| 同心县| 翁源县| 绵阳市| 洱源县| 砚山县| 远安县| 安吉县| 如东县| 慈溪市| 湟中县| 曲麻莱县| 开远市| 托克逊县| 乃东县| 洪洞县| 老河口市| 谷城县| 平原县| 页游| 仪陇县| 海口市| 杭锦旗| 灌南县| 长白| 宜丰县| 呼玛县| 綦江县| 星座| 毕节市| 湟源县| 潞西市| 凉城县| 阿巴嘎旗| 乃东县| 阿克苏市| 米易县| 河东区| 文昌市|