免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠食欲素(OX)酶聯(lián)免疫吸附檢測試劑盒
ELK8935
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat OX(Orexin) ELISA Kit
Reactivity: Rat
Alternative Names: HCRT; PPOX; Orexin A; Hypocretin 1; Orexin B; Hypocretin 2; Preproorexin; Hypocretin Neuropeptide Precursor
Assay Type: Competitive Inhibition
Sensitivity: 4.53 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 2h
Research Area: Neuro science;
Uniprot ID: O55232
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat OX protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat OX. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat OX in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 0.227
500.00 0.376
250.00 0.612
125.00 0.833
62.50 1.157
31.25 1.585
15.63 1.793
0.00 2.028

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OX and the recovery rates were calculated by comparing the measured value to the expected amount of OX in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 83-98% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OX and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-105% 85-93% 82-90%
EDTA plasma(n=5) 79-92% 88-96% 77-91% 85-93%
Heparin plasma(n=5) 88-102% 86-92% 88-97% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
南涧| 扎兰屯市| 洮南市| 漾濞| 杭州市| 海淀区| 射阳县| 尼勒克县| 海宁市| 宜都市| 盐源县| 台安县| 新民市| 民乐县| 开远市| 鹤岗市| 金沙县| 哈巴河县| 武汉市| 尼木县| 吉水县| 乐昌市| 六枝特区| 丰城市| 日喀则市| 申扎县| 金平| 景德镇市| 巴彦淖尔市| 南华县| 罗平县| 鹤山市| 崇仁县| 育儿| 内乡县| 林周县| 昌邑市| 济阳县| 佳木斯市| 诸暨市| 桓台县|