免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人組織因子(TF)酶聯(lián)免疫吸附檢測試劑盒
ELK9399
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human TF(Tissue Factor) ELISA Kit
Reactivity: Human
Alternative Names: CD142; FIII; F3; TFA; Thromboplastin; Coagulation Factor III
Assay Type: Sandwich
Sensitivity: 2.63 pg/mL
Standard: 400 pg/mL
Detection Range: 6.25-400 pg/mL
Sample Type: plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Hematology;Cardiovascular biology;
Uniprot ID: P13726
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TF in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
400.00 2.035 1.948
200.00 1.663 1.576
100.00 1.128 1.041
50.00 0.907 0.820
25.00 0.532 0.445
12.50 0.305 0.218
6.25 0.258 0.171
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TF and the recovery rates were calculated by comparing the measured value to the expected amount of TF in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 93-101% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-106% 88-103% 81-98% 78-90%
EDTA plasma(n=5) 95-102% 95-103% 87-98% 93-105%
Heparin plasma(n=5) 88-101% 86-97% 87-102% 89-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
高平市| 临清市| 永济市| 林甸县| 平安县| 河北省| 黄大仙区| 阳城县| 涿鹿县| 乐至县| 上林县| 磴口县| 高要市| 肃宁县| 本溪市| 菏泽市| 台前县| 澳门| 莒南县| 永丰县| 丘北县| 宜宾县| 大埔县| 灵宝市| 阳新县| 昭平县| 三穗县| 浦东新区| 巩义市| 商南县| 高邮市| 罗山县| 揭阳市| 成武县| 洪湖市| 阿拉善左旗| 方正县| 遵义县| 阿勒泰市| 休宁县| 巧家县|