免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人酪氨酸受體激酶B (TrkB)酶聯(lián)免疫吸附檢測試劑盒
ELK9411
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human TrkB (Tyrosine Receptor Kinase B) ELISA Kit
Reactivity: Human
Alternative Names: Tyrosine Receptor Kinase B
Assay Type: Sandwich
Sensitivity: 0.063 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TrkB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TrkB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TrkB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TrkB in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.154 2.065
5.00 1.631 1.542
2.50 1.043 0.954
1.25 0.921 0.832
0.63 0.614 0.525
0.32 0.357 0.268
0.16 0.226 0.137
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TrkB and the recovery rates were calculated by comparing the measured value to the expected amount of TrkB in samples.
Matrix Recovery range Average
serum(n=5) 82-98% 90%
EDTA plasma(n=5) 87-102% 94%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TrkB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 89-97% 85-94% 87-98%
EDTA plasma(n=5) 92-101% 83-98% 86-96% 86-97%
Heparin plasma(n=5) 88-95% 92-101% 96-105% 93-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
兴国县| 兴城市| 黄龙县| 临高县| 常宁市| 钟祥市| 甘孜县| 顺平县| 土默特右旗| 海阳市| 岳西县| 丘北县| 南部县| 塔河县| 天祝| 花莲县| 仁布县| 柳州市| 四川省| 岑巩县| 华坪县| 黄石市| 银川市| 南雄市| 虹口区| 山丹县| 湖南省| 托克逊县| 兴文县| 彭泽县| 渭南市| 印江| 涿鹿县| 靖西县| 社旗县| 乃东县| 巫溪县| 孝义市| 星子县| 东辽县| 汝城县|